RARE CONTEXT Request research

Powered land · Haringey, England

3.8 ha brownfield site at St Anns General Hospital St Anns Road London N15 3TH, Haringey

A brownfield site of 3.8 ha in Haringey, England, on the brownfield land register as previously developed land. It lies 1.01 km from the Central Tottenham Primary 11kV substation (UK Power Networks, East England licence area), which has 6.5 MVA of demand headroom and 28.7 MVA for generation.

Owner, grid capacity and planning status on request.We do not publish owners. Ask us and we look up the registered owner of this site at HM Land Registry, the headroom and connection queue at the nearest substation and its planning history, and find out whether the site is available.

Looking for more sites like this one? A powered-land shortlist picks about 20 sites for your brief in a region you name, with grid capacity, zoning, permits and owners, in 5 working days. See a sample.

Map: where 3.8 ha brownfield site at St Anns General Hospital St Anns Road London N15 3TH, Haringey lies
51.5809, -0.0917 on OpenStreetMap

Facts

Every value links to its source. Licences and last-checked dates are per row.

FactValueSource
Area3.8 ha (the area its register gives)Rare Context powered-land sites · ODbL 1.0 · checked 25 Oct 2026
Site fromBrownfield land register (England)Rare Context powered-land sites · ODbL 1.0 · checked 25 Oct 2026
Owner typePublic bodyplanning.data.gov.uk · record · Open Government Licence v3.0 · checked 25 Oct 2026
Planning permissionGrantedplanning.data.gov.uk · record · Open Government Licence v3.0 · checked 25 Oct 2026
AddressSt Anns General Hospital St Anns Road London N15 3THplanning.data.gov.uk · record · Open Government Licence v3.0 · checked 25 Oct 2026
Permit date10 Jul 2015 (full-planning-permission, issued by London Borough of Haringey)planning.data.gov.uk · record · Open Government Licence v3.0 · checked 25 Oct 2026
Register referenceHGY/2014/1691 (planning authority London Borough of Haringey)planning.data.gov.uk · record · Open Government Licence v3.0 · checked 25 Oct 2026
Register entryBrownfield site: St Anns General Hospital St Anns Road London N15 3THplanning.data.gov.uk · record · Open Government Licence v3.0 · checked 25 Oct 2026
Adopted local planHaringey's Local Plan Strategic Policies 2013-2026 Consolidated with alterations since 2017 (London Borough of Haringey; adopted 24 Jul 2017)planning.data.gov.uk · Open Government Licence v3.0 · checked 25 Oct 2026
Conservation areaSt Anns (34% of the site, estimated from the register's point and area; London Borough of Haringey; since 2 Apr 1987)planning.data.gov.uk · record · Open Government Licence v3.0 · checked 25 Oct 2026
Not designatedancient woodland, Article 4 direction, green belt, National Landscape (AONB), national park, Ramsar wetland, registered park and garden, scheduled monument, Special Area of Conservation (Natura 2000), Special Protection Area (Natura 2000), Site of Special Scientific Interest, World Heritage Site buffer zone and World Heritage Site (checked against the published areas)planning.data.gov.uk · Open Government Licence v3.0 · checked 25 Oct 2026
LocationHaringey, EnglandRare Context powered-land sites · ODbL 1.0 · checked 25 Oct 2026
Coordinates51.5809, -0.0917 (the register's point for the site)Rare Context powered-land sites · ODbL 1.0 · checked 25 Oct 2026
Nearest substationCentral Tottenham Primary 11kV (1.01 km, register point to the substation's mapped point)Rare Context powered-land sites · ODbL 1.0 · checked 25 Oct 2026
Substation voltage11 kVUK Power Networks open data portal · CC BY 4.0 · checked 25 Oct 2026
Substation operatorEastern Power Networks plc (UK Power Networks, East England licence area)UK Power Networks open data portal · CC BY 4.0 · checked 25 Oct 2026
Demand headroom at the substation6.5 MVAUK Power Networks open data portal · CC BY 4.0 · checked 25 Oct 2026
Generation headroom at the substation28.7 MVAUK Power Networks open data portal · CC BY 4.0 · checked 25 Oct 2026
Large generation within 10 km55 MW of waste-to-energy (1 plant of 50 MW or more in operation)Rare Context powered-land sites · ODbL 1.0 · checked 25 Oct 2026
Water stressHigh (40–80%) (score 3.4 of 5, withdrawals 52.2% of renewable supply)WRI Aqueduct 4.0 · CC BY 4.0 · checked 25 Oct 2026

The register gives a point and an area, not an outline: the distance runs from that point, so the site's edge can be closer to the substation.

How it compares

#35 of 38 sites in Haringey and #6,786 of 8,607 in the United Kingdom by site score. Larger than 68% of the sites in Haringey. Closer to its substation than 42% of them.

PartThis sitePointsOf
Area3.8 ha030
Distance to the substation1.01 km14.930
Demand headroom at the substation6.5 MVA6.540
Site score21100

How the site score works in the United Kingdom · Search sites in Haringey

Nearby sites on the same substation

2 other sites have Central Tottenham Primary 11kV as nearest substation and would compete for its capacity.