Data center · England, United Kingdom

Venture West data centre

Venture West data centre is a data centre in England, United Kingdom, with a 1,749 m² building, operated by The Bunker Secure Hosting Ltd. It lies 3 km from a 33 kV substation and is in an area of high water stress.

Power and water

The nearest substation is St Johns Primary, a 33 kV primary substation run by Southern Electric Power Distribution plc, 3 km away. Its network operator publishes 4.6 MVA of demand headroom and 0 MW of generation headroom there, and the network there is not congested for new demand.

No power plant of 50 MW or more is in operation within 10 km, in the plant registers we hold.

Water stress here is high: withdrawals take 52.2% of the renewable water supply of its sub-basin (WRI Aqueduct 4.0, baseline, score 3.4 of 5).

Distances run between the points of the records. How the grid and plants nearby are found; water stress from WRI Aqueduct 4.0.

Facts

Every value links to its source, and to the source's own record where it has one. Licences and last-checked dates are per row.

FactValueSource
LocationEnglandOpenStreetMap data centers · record · ODbL 1.0 · checked 24 Oct 2026
OperatorThe Bunker Secure Hosting LtdOpenStreetMap data centers · record · ODbL 1.0 · checked 24 Oct 2026
Websitehttp://www.thebunker.net/our-data-centres/#newburyOpenStreetMap data centers · record · ODbL 1.0 · checked 24 Oct 2026
Nearest substationSt Johns Primary (3.03 km away, at 33 kV, primary substation)Rare Context powered-land sites · ODbL 1.0 · checked 25 Oct 2026
Water stressHigh (40–80%) (score 3.4 of 5, withdrawals 52.2% of renewable supply)WRI Aqueduct 4.0 · CC BY 4.0 · checked 25 Oct 2026
Building footprint1,749 m² (building)OpenStreetMap data centers · record · ODbL 1.0 · checked 24 Oct 2026
Coordinates51.3770, -1.2905OpenStreetMap data centers · record · ODbL 1.0 · checked 24 Oct 2026

Research on this data center and its operator.Who owns it up to the parent company, its power supply, grid connection and planning status, and an introduction to the operator.

Request research

Nearby

Within 50 km of this data center: 315 power plants (118 operating, 3,441 MW), 252 grid connections (133 operating, 1,398 MW) and 244 substations, measured from the coordinates in the facts above. The table shows the nearest 9, up to 3 per kind.

NameKindSizeStatusDistance
New Greenham Park (gasification)Power plant6.3 MWCancelled0.3 km
St Johns PrimarySubstation——3.0 km
Riverside PrimarySubstation——3.2 km
Limberlost Farm grid connectionGrid connection1.62 MWOperating3.5 km
Gas 9.5 MW grid connection at ThatchamGrid connection9.5 MWOperating3.8 km
Thatcham PrimarySubstation——3.8 km
Kingsclere Solar Farm grid connectionGrid connection23 MWPlanned4.1 km
Strattons Farm, Newbury Road - Solar PV FarmPower plant23 MWPlanned4.2 km
Limberlost FarmPower plant1.5 MWOperating4.3 km

Operator and place

Other data centers in England

All 245 data centers in England, United Kingdom

Data on this page